Link-systems OmniLink 5000 Manual do Utilizador Página 26

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 25
4.8
Group 5 Programmed in Factory Mode Configuration.
45 Allow Timed Inch (value)
46 Allow Auto Single Stroke (value)
47 Allow Continuous on Demand (value)
48 Allow Maintain Continuous (value)
49 Maximum Auto Single Stroke time (value)
50 Max. Continuous on Demand time (value)
Section 4.2.9.4 Event Log
The controls retains a event log. This log records the reason for the last 128 stops. All reasons for last stop
are recorded, except automatic stop on top. Each entry in the event log contains the time, date, and the type
of stop. The event log is illustrated in Figure 4.4. Stops are displayed in chronological order with the most
recent stop displayed first. The Next Page and Previous Page softkeys can be used to scroll through the
event log.
Stroke
Mode
Sin
g
le Stroke
Drive
Speed
Stroke
Speed
SPM
SPM
0
0
Order
Counter
PC STATUS
Counter OFF
EVENT
LOG
EXIT
0
0
READY TO STROKE
TOP
NEXT
PAGE
PREVIOUS
PAGE
Date TimeSubs
y
stem
------------------ ------------------- -------------------------------------
3/21/2000 14:59:41 Event Lo
g
Subs
y
stem
Reason: To
p
Sto
p
3/21/2000 14:59:02 Event Lo
g
Subs
y
stem
Reason: Li
g
ht Curtain # 1
3/21/2000 14:50:49 Event Lo
g
Subs
y
stem
Reason: Die Block
3/21/2000 14:49:22 Event Lo
g
Subs
y
stem
Reason: Auxiliar
y
To
p
Sto
p
3/21/2000 14:44:18 Event Lo
g
Subs
y
stem
Reason: To
p
Sto
p
3/21/2000 14:42:29 Event Lo
g
Subs
y
stem
Reason: To
p
Sto
p
3/21/2000 14:38:48 Event Lo
g
Subs
y
stem
Reason: To
p
Sto
p
3/21/2000 14:32:59 Event Lo
g
Subs
y
stem
Reason: To
p
Sto
p
Figure 4.4 Event Log
Section 4.2.9.5 Version Information
The version information of the control hardware and software can be viewed by depressing the VERSION
INFO. softkey.
Section 4.2.10 RESET ERROR
The press control screen alerts the operator of an error condition by displaying a RESET ERROR softkey
as shown in Figure 4.5. The reason for the error is shown under Present Running Status. The press can not
be operated until the error is corrected and an operator acknowledges the error by pressing the RESET
ERROR softkey. See the section on Troubleshooting for conditions that require an operator's response.