Link-systems OmniLink 5000 Manual do Utilizador Página 25

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 24
4.7
Group 2 Programmed in Top Stop Calibration (configuration).
06 Speed Range (lowest)
07 Stop position (in single stroke)
08 Stop position (in continuous)
09 Speed Range (1/3 range)
10 Stop position (in single stroke)
11 Stop position (in continuous)
12 Speed Range (2/3 range)
13 Stop position (in single stroke)
14 Stop position (in continuous)
15 Speed Range (highest)
16 Stop position (in single stroke)
17 Stop position (in continuous)
18 Stop position in setup/stop time mode
Group 3 Programmed in Machine Parameters (configuration).
19 Resolver/encoder offset
20 Automatic carry up position
21 Begin timed inch position
22 Minimum strokes/min
23 Maximum strokes/min
24 Motion filter
25 Clutch engagement time
26 Timed inch pulse duration
27 Automatic turn off time
28 Maximum # Engagements/Minute
Group 4 Programmed in Factory Configuration Machine Parameters.
29 Hydraulic Overload type (value)
30 Inch Button Config (value)
31 Input configuration (value)
32 Output configuration (value)
33 Tonnage monitor type (value)
34 Die protection type (value)
35 Automatic Setups (value)
36 Light curtain mute type (value)
37 Feed line type (value)
38 Valve monitor type (value)
39 Valve monitor pull in time (value/10)
40 Valve monitor drop out time (value/10)
41 Valve monitor track time (value/10)
42 Main motor delayed turn on time (value)
43 Main motor delayed turn off time (value)
44 Reserved Factory parameter (value)