Link-systems System 1100 Tonnage Monitor Manual do Utilizador Página 114

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 117
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 113
ERROR CODES
___________________________________________________________________
Error No. Message / Action
10-11
The Data window 2 high setpoint of the channel
indicated by the error code is set to a value less
than the low setpoint.
1) Adjust the high or low setpoint so that the high
setpoint is greater than the low setpoint.
096 Data window 3, channel 1 high setpoint too high.
097 Data window 3, channel 2 high setpoint too high.
098 Data window 3, channel 3 high setpoint too high.
099 Data window 3, channel 4 high setpoint too high.
The Data window 3 high setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1) Check the MACH RATING setting in the Config menu
for correctness.
2) Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
100 Data window 3, channel 1 low setpoint too high.
101 Data window 3, channel 2 low setpoint too high.
102 Data window 3, channel 3 low setpoint too high.
103 Data window 3, channel 4 low setpoint too high.
The Data window 3 low setpoint of the channel
indicated by the error code is set to a value
greater than 125% of the channel rating.
1) Check the MACH RATING setting in the Config menu
for correctness.
2) Adjust the indicated setpoint to a setting less
than 125% of the channel rating.
104 Data window 3, channel 1 reverse setpoint too high.
105 Data window 3, channel 2 reverse setpoint too high.
106 Data window 3, channel 3 reverse setpoint too high.
Vista de página 113
1 2 ... 109 110 111 112 113 114 115 116 117

Comentários a estes Manuais

Sem comentários